Environment
The altitude of the installation place should not exceed 1000m; if it exceeds 1000m, the capacity should be reduced;
The ambient temperature is -10~40℃, above 40℃, the capacity should be reduced, and the current should be reduced by 2% for every 1℃ above.
Ambient humidity ≤95%RH, no water condensation;
●Indoor without corrosive gas that destroys metal and insulating materials:
●No direct sunlight, no dust, combustible gas, oil mist, dripping water or salt.
| Item | Project Description | |
| Applicable standards | GB14048.6-2016(IEC947-4-2) | |
| Applicable motor type | Squirrel-cage three-phase asynchronous motors | |
| Motor power | 11A……1260A(5.5~630kW) | |
| Control Voltage | AC220V±15%;50Hz/60Hz;AC110V±15% | |
| input | Rated Voltage | AC380V±15%;50Hz/60Hz;660V±15% |
| Adjustable start time | 1~120s adjustable | |
| Adjustable stopping time | 0~120s adjustable | |
| control mode | 1.Ramp voltage 2.Ramp current 3.Current limit mode | |
| I/0 | Logic Inputs | 3 way(X1~X3) |
| Analog Outputs | 1 channel 4~20mA/0~10V | |
| Relay outputs | 2 relay outputs | |
| Run command inputs | Keyboard display unit given, control terminal given | |
| RS485 communication given | ||
| Communication | Integrated communication protocols | Standard Modbus protocol, 1 channel |
| Display Unit | LCD display | Can display current, voltage, alarm and other motor parameters |
| Protection and monitoring | Short-circuit, over-voltage, overload, under-voltage, phase loss, over-current, temperature protection | |
| matrix | Location | Indoor, not subject to direct sunlight, no dust, corrosive, flammable gases, oil mist, |
| water vapor, dripping water or salt, etc. | ||
| altitude | Altitude more than 1000m, the capacity should be reduced accordingly, every increase of 100m, the current is reduced. | |
| Environmental humidity | -10℃~+40℃; -40℃ or above shall be used at a reduced capacity. | |
| Above 40℃ shall be used at reduced capacity | ||
| For every 1℃, the current shall be reduced by 2%. | ||
| Temperature | Less than 95%RH, no water droplet condensation. | |
| Vibration | Less than 5 .9m/s2(0 .6g) | |
| Storage Temperature | -40℃~70℃ | |
| framework | Protection class | Ip20 |
| Cooling method | Radiator, natural cooling | |
| Installation | Vertical installation in cabinet | |